LiPo Storage Voltage Guide: 1S to 6S Tables

Store a LiPo battery at about 3.8V per cell: about 7.6V for a 2S pack, 11.4V for a 3S pack, 15.2V for a 4S pack, and 22.8V for a 6S pack. Use your charger storage mode to get there, check each cell first, and re-check stored packs every two to four weeks. Never store a pack full at 4.20V per cell for weeks, and never store one flat near 3.0V per cell. The 3.8V figure is the commonly cited figure, not a manufacturer spec.

What is LiPo storage voltage?

Storage voltage is the per-cell voltage a LiPo pack rests at between uses. For a standard LiPo pack the commonly cited target is about 3.8V per cell, with published guides giving a 3.80 to 3.85V range. It sits in the middle: full is 4.20V per cell, the floor is about 3.0V per cell.

A pack left fully charged rests at maximum voltage, where the side reactions inside the cell run fastest: capacity fades, internal resistance climbs, and gas builds up, which is the puffing pilots recognise. Heat makes all of it worse. A pack left empty fails the other way: resting voltage drifts slowly downward until the damage is structural and irreversible, and charging a deeply over-discharged cell is a safety problem, not a recovery project. Storage voltage avoids both at once.

About 3.8V per cell is a commonly cited figure, not a manufacturer spec, and no official datasheet was found for the packs QRC stocks. Sources disagree slightly on the band: SwellRC gives 3.80 to 3.85V per cell, HobbyKing gives 3.7 to 3.85V, and Gens Ace gives a wider 3.6 to 3.9V, reported in the Medium storage guide. This draft uses 3.80 to 3.85V as the target band and treats 3.7 to 3.85V as acceptable, where the sources overlap.

Storage voltage is a per-cell number, not a pack total. A 4S pack at storage reads about 15.2V total, but the four individual cell readings are the real record, because cells drift apart as packs age. Judge a pack by its worst cell, not its total.

What voltage do you store each pack at?

Multiply the per-cell figure by the number of cells. A pack is on target when every cell reads inside the 3.80 to 3.85V band.

Pack Full (4.20V per cell) Storage low (3.80V per cell) Storage high (3.85V per cell) Nominal (3.70V per cell) Minimum (about 3.0V per cell)
1S 4.20V 3.80V 3.85V 3.70V About 3.0V
2S 8.40V 7.60V 7.70V 7.40V About 6.0V
3S 12.60V 11.40V 11.55V 11.10V About 9.0V
4S 16.80V 15.20V 15.40V 14.80V About 12.0V
5S 21.00V 19.00V 19.25V 18.50V About 15.0V
6S 25.20V 22.80V 23.10V 22.20V About 18.0V

A 3S pack is on target when every cell reads between 11.40V and 11.55V total. Do not aim for the nominal voltage: 3.70V per cell is the average label figure, not a storage target. Never charge a standard LiPo cell past 4.20V, and never run a cell below about 3.0V at rest: cells run that low are damaged, and many chargers will refuse them.

What does a voltage reading mean?

Read each cell on the checker, find the band, and act on the lowest cell, not the average.

Per-cell reading What it means What to do
Above 4.20V Overcharged Do not charge it or fly it. Retire the pack.
4.20V Full Fine if you fly within a day or two. Storage-charge it down if the pack will sit longer.
3.86V to 4.19V Above the storage band Storage-charge it down before the pack sits for more than a few days.
3.80V to 3.85V On target for storage Put it away. Re-check every two to four weeks.
3.70V to 3.79V Below target, inside the wider range Fine for a short rest. Top it back to target for a long rest.
3.60V to 3.69V Low for storage Bring it back to storage voltage soon. Watch the low cell.
Below 3.60V Too low to leave sitting Bring it back promptly. Never store below 3.6V per cell.
About 3.0V or below Damaged, likely unrecoverable Do not force it on NiMH mode. Retire the pack.
0.00V on one cell Dead cell The pack is done. Retire it and dispose of it following local rules.

The bands follow the cited ranges, not a maker spec: 3.80 to 3.85V from SwellRC, 3.7 to 3.85V from HobbyKing, 3.6 to 3.9V from Gens Ace as reported in the Medium storage guide, and the 3.6V floor from Hanery. Your pack maker guidance wins when it gives its own number.

After a storage cycle the cells should read close together; a cell clearly apart from its siblings is a flag. At full charge, every cell should read 4.20V, or within about 0.03V of it.

How do you check a pack before storage?

Check the pack cell by cell, every time, before it goes on the shelf.

  1. Let the pack cool. Wait until the pack is at room temperature. Never charge a hot pack, and never charge a frozen or very cold pack.
  2. Inspect the pack. Do not storage-charge a swollen, hot, leaking, punctured, or crushed pack.
  3. Plug the balance lead into the checker. The CellMeter8 LiPo Battery Checker (ID 3485) reads up to 8 cells through the balance lead, and the 3-in-1 Battery Voltage Checker Balancer and Discharger (ID 12052) shows cell voltages on its LCD display. Plug it in fully and wait for the reading to settle.
  4. Read every cell, not the total. The lowest cell decides what happens next, using the reading bands table above.
  5. Unplug the pack from the model first. A switched-off model is not a disconnected model. Unplug the main lead after every session, so nothing can drain the pack while it sits.

A multimeter on the main lead is a weaker check: it reads the pack total only, so it cannot see a single low cell hiding inside a healthy-looking total. The Jönköping chapter uses a multimeter on the XT60 contacts to read a 3S pack total, between about 11.1V at storage and 12.6V full. For storage, use a checker that reads each cell.

How do you storage-charge a pack on a balance charger?

Storage mode works in both directions: it charges a flown pack up, and it discharges a full pack down. Run it after every session for packs you will not use within a day or two. The steps below use the B6 80W Mini LiPo Balance Charger and Discharger with Power Supply (ID 18960), whose listing states a storage charge function, 1 to 6 cells, and LiPo, Li-ion, and LiFe support.

  1. Let the pack cool, inspect it, and put it in the safe bag. Never storage-charge a swollen, hot, or damaged pack. Set the Zeee Small LiPo Safe Bag (ID 20106) on a non-flammable surface, pack inside, leads out where you can reach them.
  2. Connect the main lead, then the balance lead. Without it the charger steers by the pack total, and one high cell can finish above the target.
  3. Select LiPo storage mode. Not balance charge, not fast charge, not plain charge.
  4. Confirm the cell count on the display. It should match the label. If it shows fewer cells, or a cell reads 0.00V, stop.
  5. Start the cycle and stay in the room. A storage discharge takes longer than a storage charge, because most hobby chargers can only shed a small amount of power as heat when discharging. Start storage work when flying ends.
  6. Verify with the checker when the charger reports done. Every cell should read 3.80 to 3.85V. Flag a cell that sits clearly apart.
  7. Unplug the balance lead first, then the main lead. Label the pack with the date and the word storage.

How do you storage-charge with the stocked checker and discharger?

3-in-1 Battery Voltage Checker Balancer and Discharger (ID 12052), $12.49. The listing states it checks pack voltage, balances cells, and discharges packs for storage, with cell voltages on its LCD display. Use it to bring a full pack down to storage voltage: plug in the balance lead, read each cell, select the discharge mode, and verify that every cell lands in the 3.80 to 3.85V band. It discharges; it does not charge a flown pack up. Run it on a non-flammable surface with its airflow unobstructed, attended, because it gets hot doing its job.

CellMeter8 LiPo Battery Checker (ID 3485), $19.99. A checker and balancer for up to 8 cells. It reads each cell through the balance lead, which is the check this whole guide depends on. It does not charge or discharge, so pair it with the B6 80W Mini for the storage cycle.

ImaxRC B3 Pro Balance Charger (2S/3S) (ID 16863), $15.99. A compact balance charger for 2S and 3S LiPo packs only, per its listing, which states no storage program: check the manual before you count on one.

No storage mode on your charger? Charge the pack and stop when the per-cell reading reaches about 3.8V, watching the checker as it climbs. That tip follows the Medium storage guide: after a normal run a pack is usually below storage voltage. If the pack is full instead, run the charger discharge function, or use the 3-in-1 discharger above.

How long can a pack sit at each voltage?

How long a pack can sit depends on where it starts.

Starting voltage How long it can sit What to do
Full, 4.20V per cell A day or two Normal between sessions. Past that, storage-charge it down.
Storage, 3.80 to 3.85V per cell Weeks to months, with checks The resting state. Re-check every two to four weeks.
Nominal, 3.70V per cell Weeks, with checks Below the target band, so it has less margin. Top it back to the storage band before a long rest.
Flat, below 3.60V per cell Do not leave it sitting Bring it back promptly. A flat pack left over 7 days can over-discharge, per Traxxas guidance.
Below about 3.0V per cell Already damaged Do not store or force-charge it. Retire the pack.

The sources split on check cadence: the QRC storage guide says every two to four weeks, Gens Ace suggests every few months. This draft recommends the two to four week check. Label every pack with its storage date and a rough cycle count.

For a winter or off-season rest, put every pack at storage voltage before the break, keep them in a cool, dry, stable indoor spot, and keep the two to four week check going. Before the first use after a long rest, balance-charge the pack and check that all cell voltages ended close together.

What about LiHV and LiFe packs?

LiHV and LiFe packs are not standard LiPo packs. Check the label: the chemistry is printed on the pack, and the setting must match it.

LiHV packs charge to 4.35V per cell instead of 4.20V and need the LiHV setting; charging a normal LiPo on it overcharges it. Use the storage mode your charger specifies for LiHV packs where it offers one. Where it does not, rest LiHV packs at the same about 3.8V per cell region as standard LiPos, per the DroneCamps storage guide; the RobotCombatWiki safety page gives about 3.8 to 3.85V per cell. A LiHV pack left at its full 4.35V rests harder than a standard pack left at 4.20V, so bring LiHV packs down promptly.

LiFe packs use their own setting with a full voltage of about 3.6V per cell, per SwellRC. The RobotCombatWiki safety page gives about 3.3V per cell as the LiFe storage figure. Treat that figure as less settled: it comes from one safety page. Follow the LiFe pack maker docs first.

Never charge a standard LiPo on the LiHV setting, and never charge a LiHV pack on a setting you have not confirmed matches its label.

Which storage setup fits your fleet?

Situation Voltage action Gear
Flying in a few days to a week Storage-charge now, so a cancelled session never strands a full pack B6 80W Mini charger (ID 18960)
Not flying for weeks or months Storage voltage, safe bag, checks every two to four weeks B6 80W Mini charger (ID 18960), Zeee safe bag (ID 20106)
Winter or off-season rest Storage voltage before the break, cool dry spot B6 80W Mini charger (ID 18960), Zeee safe bag (ID 20106)
Pack came home full and unflown Discharge it down to storage, do not leave it full 3-in-1 discharger (ID 12052) or B6 80W Mini (ID 18960)

What mistakes ruin packs in storage?

Most stored packs are not ruined by one dramatic mistake. Smaller habits repeat over time.

Mistake What happens Fix
Storing packs full for weeks Cells age fastest at full voltage, gas builds, packs puff Storage-charge to about 3.8V per cell when the pack sits
Storing packs flat Resting voltage drifts down until a cell is damaged for good Never store a pack flat
Storage-charging without the balance lead Charger steers by the pack total, one cell can finish above target Connect the balance lead every cycle
Reading the pack total only A low cell hides inside a healthy-looking total Read each cell; judge by the worst cell
Leaving the pack plugged into the model A switched-off model can still drain the pack while it sits Unplug the main lead after every session
Storing in a hot car or in the sun Heat multiplies every ageing reaction Cool, dry, stable indoor spot, out of direct sun
Packing packs loose together or sealed airtight Loose packs can short terminal to terminal; a failing cell vents gas a sealed box cannot release Keep plugs capped or packs separated, use a vented container or a LiPo safe bag
Forgetting stored packs for months Drift goes unnoticed until a cell is too low to save Check every two to four weeks, label each pack

Why is my pack off storage voltage?

The storage discharge on the charger takes hours. Normal: charger discharge power is small by design. Start storage work when flying ends, or use a dedicated discharger set to the storage endpoint, such as the 3-in-1 checker and discharger (ID 12052).

One cell always finishes below the others. That cell is ageing faster than its siblings. Flag the pack and retire it when the spread keeps growing.

A pack was found resting near empty after a long break. Self-discharge plus time; it was likely stored low or left connected to a load. If any cell is deeply over-discharged, treat it as end of life and dispose of it safely rather than charging it.

The charger reports a low-voltage error and will not start a storage cycle. One or more cells dropped below the safe level, typically about 3.0V per cell. The pack was run too flat, left plugged in, or stored flat. Do not force it by charging on NiMH mode: that bypasses the safety cutoff that refused the pack. If a cell reads 0.00V, the pack is done.

Parts used in this guide

Prices and stock verified live 2026-11-21; all four are in stock and purchasable.

Also named in the body text, verified live in stock and purchasable on 2026-11-21: ImaxRC B3 Pro Balance Charger (2S/3S) (ID 16863) – $15.99. 2S and 3S LiPo only. No storage program is stated in its listing.

Shipped fast and securely from our secure facility in Queensbury, NY, providing fast, high quality USA shipping. QRC ships within the USA only.

Related guides

FAQ

What is the storage voltage for a LiPo battery? About 3.8V per cell, with published guides giving a 3.80 to 3.85V range. A 3S pack stores at about 11.4V and a 6S pack at about 22.8V. Source: SwellRC, Jönköping University, and DroneCamps guides.

What voltage should a 2S or 3S LiPo be stored at? About 7.6V for a 2S pack and 11.4V for a 3S pack, roughly 3.8V per cell. Source: Medium storage guide.

How long can a LiPo stay fully charged? A day or two is normal between sessions. Smart packs start discharging to storage after 72 hours by default. Past that, storage-charge the pack down. Source: Medium storage guide.

Can I store LiPos in the fridge? No. A fridge brings moisture and condensation when the pack comes back out. A cool, dry room is enough, and a cold pack should return fully to room temperature before charging or use. Source: HobbyKing storage guide and Medium storage guide.

Is a slightly puffy pack still safe to use? No. Never use a LiPo that feels soft or has swollen. Retire it and dispose of it through a battery recycling point. Do not puncture it, press it flat, or charge it one more time. Source: Medium storage guide and DroneCamps storage guide.

How often should I check stored LiPo packs? Every two to four weeks, per the QRC storage guide. Source: QRC storage guide 19753.

Sources

Last updated: 2026-11-21