LiPo Storage Voltage Guide: 1S to 6S Tables

Store a LiPo battery at about 3.8V per cell: about 7.6V for a 2S pack, 11.4V for a 3S pack, 15.2V for a 4S pack, and 22.8V for a 6S pack. Use your charger storage mode to get there, check each cell first, and re-check stored packs every two to four weeks. Never store a pack full at 4.20V per cell for weeks, and never store one flat near 3.0V per cell. The 3.8V figure is the commonly cited figure, not a manufacturer spec.

What is LiPo storage voltage?

Storage voltage is the per-cell voltage a LiPo pack rests at between uses. For a standard LiPo pack the commonly cited target is about 3.8V per cell, with published guides giving a 3.80 to 3.85V range. It sits in the middle: full is 4.20V per cell, the floor is about 3.0V per cell.

A pack left fully charged rests at maximum voltage, where the side reactions inside the cell run fastest: capacity fades, internal resistance climbs, and gas builds up, which is the puffing pilots recognise. Heat makes all of it worse. A pack left empty fails the other way: resting voltage drifts slowly downward until the damage is structural and irreversible, and charging a deeply over-discharged cell is a safety problem, not a recovery project. Storage voltage avoids both at once.

About 3.8V per cell is a commonly cited figure, not a manufacturer spec, and no official datasheet was found for the packs QRC stocks. Sources disagree slightly on the band: SwellRC gives 3.80 to 3.85V per cell, HobbyKing gives 3.7 to 3.85V, and Gens Ace gives a wider 3.6 to 3.9V, reported in the Medium storage guide. This draft uses 3.80 to 3.85V as the target band and treats 3.7 to 3.85V as acceptable, where the sources overlap.

Storage voltage is a per-cell number, not a pack total. A 4S pack at storage reads about 15.2V total, but the four individual cell readings are the real record, because cells drift apart as packs age. Judge a pack by its worst cell, not its total.

What voltage do you store each pack at?

Multiply the per-cell figure by the number of cells. A pack is on target when every cell reads inside the 3.80 to 3.85V band.

Pack Full (4.20V per cell) Storage low (3.80V per cell) Storage high (3.85V per cell) Nominal (3.70V per cell) Minimum (about 3.0V per cell)
1S 4.20V 3.80V 3.85V 3.70V About 3.0V
2S 8.40V 7.60V 7.70V 7.40V About 6.0V
3S 12.60V 11.40V 11.55V 11.10V About 9.0V
4S 16.80V 15.20V 15.40V 14.80V About 12.0V
5S 21.00V 19.00V 19.25V 18.50V About 15.0V
6S 25.20V 22.80V 23.10V 22.20V About 18.0V

A 3S pack is on target when every cell reads between 11.40V and 11.55V total. Do not aim for the nominal voltage: 3.70V per cell is the average label figure, not a storage target. Never charge a standard LiPo cell past 4.20V, and never run a cell below about 3.0V at rest: cells run that low are damaged, and many chargers will refuse them.

What does a voltage reading mean?

Read each cell on the checker, find the band, and act on the lowest cell, not the average.

Per-cell reading What it means What to do
Above 4.20V Overcharged Do not charge it or fly it. Retire the pack.
4.20V Full Fine if you fly within a day or two. Storage-charge it down if the pack will sit longer.
3.86V to 4.19V Above the storage band Storage-charge it down before the pack sits for more than a few days.
3.80V to 3.85V On target for storage Put it away. Re-check every two to four weeks.
3.70V to 3.79V Below target, inside the wider range Fine for a short rest. Top it back to target for a long rest.
3.60V to 3.69V Low for storage Bring it back to storage voltage soon. Watch the low cell.
Below 3.60V Too low to leave sitting Bring it back promptly. Never store below 3.6V per cell.
About 3.0V or below Damaged, likely unrecoverable Do not force it on NiMH mode. Retire the pack.
0.00V on one cell Dead cell The pack is done. Retire it and dispose of it following local rules.

The bands follow the cited ranges, not a maker spec: 3.80 to 3.85V from SwellRC, 3.7 to 3.85V from HobbyKing, 3.6 to 3.9V from Gens Ace as reported in the Medium storage guide, and the 3.6V floor from Hanery. Your pack maker guidance wins when it gives its own number.

After a storage cycle the cells should read close together; a cell clearly apart from its siblings is a flag. At full charge, every cell should read 4.20V, or within about 0.03V of it.

How do you check a pack before storage?

Check the pack cell by cell, every time, before it goes on the shelf.

  1. Let the pack cool. Wait until the pack is at room temperature. Never charge a hot pack, and never charge a frozen or very cold pack.
  2. Inspect the pack. Do not storage-charge a swollen, hot, leaking, punctured, or crushed pack.
  3. Plug the balance lead into the checker. The CellMeter8 LiPo Battery Checker (ID 3485) reads up to 8 cells through the balance lead, and the 3-in-1 Battery Voltage Checker Balancer and Discharger (ID 12052) shows cell voltages on its LCD display. Plug it in fully and wait for the reading to settle.
  4. Read every cell, not the total. The lowest cell decides what happens next, using the reading bands table above.
  5. Unplug the pack from the model first. A switched-off model is not a disconnected model. Unplug the main lead after every session, so nothing can drain the pack while it sits.

A multimeter on the main lead is a weaker check: it reads the pack total only, so it cannot see a single low cell hiding inside a healthy-looking total. The Jönköping chapter uses a multimeter on the XT60 contacts to read a 3S pack total, between about 11.1V at storage and 12.6V full. For storage, use a checker that reads each cell.

How do you storage-charge a pack on a balance charger?

Storage mode works in both directions: it charges a flown pack up, and it discharges a full pack down. Run it after every session for packs you will not use within a day or two. The steps below use the B6 80W Mini LiPo Balance Charger and Discharger with Power Supply (ID 18960), whose listing states a storage charge function, 1 to 6 cells, and LiPo, Li-ion, and LiFe support.

  1. Let the pack cool, inspect it, and put it in the safe bag. Never storage-charge a swollen, hot, or damaged pack. Set the Zeee Small LiPo Safe Bag (ID 20106) on a non-flammable surface, pack inside, leads out where you can reach them.
  2. Connect the main lead, then the balance lead. Without it the charger steers by the pack total, and one high cell can finish above the target.
  3. Select LiPo storage mode. Not balance charge, not fast charge, not plain charge.
  4. Confirm the cell count on the display. It should match the label. If it shows fewer cells, or a cell reads 0.00V, stop.
  5. Start the cycle and stay in the room. A storage discharge takes longer than a storage charge, because most hobby chargers can only shed a small amount of power as heat when discharging. Start storage work when flying ends.
  6. Verify with the checker when the charger reports done. Every cell should read 3.80 to 3.85V. Flag a cell that sits clearly apart.
  7. Unplug the balance lead first, then the main lead. Label the pack with the date and the word storage.

How do you storage-charge with the stocked checker and discharger?

3-in-1 Battery Voltage Checker Balancer and Discharger (ID 12052), $12.49. The listing states it checks pack voltage, balances cells, and discharges packs for storage, with cell voltages on its LCD display. Use it to bring a full pack down to storage voltage: plug in the balance lead, read each cell, select the discharge mode, and verify that every cell lands in the 3.80 to 3.85V band. It discharges; it does not charge a flown pack up. Run it on a non-flammable surface with its airflow unobstructed, attended, because it gets hot doing its job.

CellMeter8 LiPo Battery Checker (ID 3485), $19.99. A checker and balancer for up to 8 cells. It reads each cell through the balance lead, which is the check this whole guide depends on. It does not charge or discharge, so pair it with the B6 80W Mini for the storage cycle.

ImaxRC B3 Pro Balance Charger (2S/3S) (ID 16863), $15.99. A compact balance charger for 2S and 3S LiPo packs only, per its listing, which states no storage program: check the manual before you count on one.

No storage mode on your charger? Charge the pack and stop when the per-cell reading reaches about 3.8V, watching the checker as it climbs. That tip follows the Medium storage guide: after a normal run a pack is usually below storage voltage. If the pack is full instead, run the charger discharge function, or use the 3-in-1 discharger above.

How long can a pack sit at each voltage?

How long a pack can sit depends on where it starts.

Starting voltage How long it can sit What to do
Full, 4.20V per cell A day or two Normal between sessions. Past that, storage-charge it down.
Storage, 3.80 to 3.85V per cell Weeks to months, with checks The resting state. Re-check every two to four weeks.
Nominal, 3.70V per cell Weeks, with checks Below the target band, so it has less margin. Top it back to the storage band before a long rest.
Flat, below 3.60V per cell Do not leave it sitting Bring it back promptly. A flat pack left over 7 days can over-discharge, per Traxxas guidance.
Below about 3.0V per cell Already damaged Do not store or force-charge it. Retire the pack.

The sources split on check cadence: the QRC storage guide says every two to four weeks, Gens Ace suggests every few months. This draft recommends the two to four week check. Label every pack with its storage date and a rough cycle count.

For a winter or off-season rest, put every pack at storage voltage before the break, keep them in a cool, dry, stable indoor spot, and keep the two to four week check going. Before the first use after a long rest, balance-charge the pack and check that all cell voltages ended close together.

What about LiHV and LiFe packs?

LiHV and LiFe packs are not standard LiPo packs. Check the label: the chemistry is printed on the pack, and the setting must match it.

LiHV packs charge to 4.35V per cell instead of 4.20V and need the LiHV setting; charging a normal LiPo on it overcharges it. Use the storage mode your charger specifies for LiHV packs where it offers one. Where it does not, rest LiHV packs at the same about 3.8V per cell region as standard LiPos, per the DroneCamps storage guide; the RobotCombatWiki safety page gives about 3.8 to 3.85V per cell. A LiHV pack left at its full 4.35V rests harder than a standard pack left at 4.20V, so bring LiHV packs down promptly.

LiFe packs use their own setting with a full voltage of about 3.6V per cell, per SwellRC. The RobotCombatWiki safety page gives about 3.3V per cell as the LiFe storage figure. Treat that figure as less settled: it comes from one safety page. Follow the LiFe pack maker docs first.

Never charge a standard LiPo on the LiHV setting, and never charge a LiHV pack on a setting you have not confirmed matches its label.

Which storage setup fits your fleet?

Situation Voltage action Gear
Flying in a few days to a week Storage-charge now, so a cancelled session never strands a full pack B6 80W Mini charger (ID 18960)
Not flying for weeks or months Storage voltage, safe bag, checks every two to four weeks B6 80W Mini charger (ID 18960), Zeee safe bag (ID 20106)
Winter or off-season rest Storage voltage before the break, cool dry spot B6 80W Mini charger (ID 18960), Zeee safe bag (ID 20106)
Pack came home full and unflown Discharge it down to storage, do not leave it full 3-in-1 discharger (ID 12052) or B6 80W Mini (ID 18960)

What mistakes ruin packs in storage?

Most stored packs are not ruined by one dramatic mistake. Smaller habits repeat over time.

Mistake What happens Fix
Storing packs full for weeks Cells age fastest at full voltage, gas builds, packs puff Storage-charge to about 3.8V per cell when the pack sits
Storing packs flat Resting voltage drifts down until a cell is damaged for good Never store a pack flat
Storage-charging without the balance lead Charger steers by the pack total, one cell can finish above target Connect the balance lead every cycle
Reading the pack total only A low cell hides inside a healthy-looking total Read each cell; judge by the worst cell
Leaving the pack plugged into the model A switched-off model can still drain the pack while it sits Unplug the main lead after every session
Storing in a hot car or in the sun Heat multiplies every ageing reaction Cool, dry, stable indoor spot, out of direct sun
Packing packs loose together or sealed airtight Loose packs can short terminal to terminal; a failing cell vents gas a sealed box cannot release Keep plugs capped or packs separated, use a vented container or a LiPo safe bag
Forgetting stored packs for months Drift goes unnoticed until a cell is too low to save Check every two to four weeks, label each pack

Why is my pack off storage voltage?

The storage discharge on the charger takes hours. Normal: charger discharge power is small by design. Start storage work when flying ends, or use a dedicated discharger set to the storage endpoint, such as the 3-in-1 checker and discharger (ID 12052).

One cell always finishes below the others. That cell is ageing faster than its siblings. Flag the pack and retire it when the spread keeps growing.

A pack was found resting near empty after a long break. Self-discharge plus time; it was likely stored low or left connected to a load. If any cell is deeply over-discharged, treat it as end of life and dispose of it safely rather than charging it.

The charger reports a low-voltage error and will not start a storage cycle. One or more cells dropped below the safe level, typically about 3.0V per cell. The pack was run too flat, left plugged in, or stored flat. Do not force it by charging on NiMH mode: that bypasses the safety cutoff that refused the pack. If a cell reads 0.00V, the pack is done.

Parts used in this guide

Prices and stock verified live 2026-11-21; all four are in stock and purchasable.

Also named in the body text, verified live in stock and purchasable on 2026-11-21: ImaxRC B3 Pro Balance Charger (2S/3S) (ID 16863) – $15.99. 2S and 3S LiPo only. No storage program is stated in its listing.

Shipped fast and securely from our secure facility in Queensbury, NY, providing fast, high quality USA shipping. QRC ships within the USA only.

Related guides

FAQ

What is the storage voltage for a LiPo battery? About 3.8V per cell, with published guides giving a 3.80 to 3.85V range. A 3S pack stores at about 11.4V and a 6S pack at about 22.8V. Source: SwellRC, Jönköping University, and DroneCamps guides.

What voltage should a 2S or 3S LiPo be stored at? About 7.6V for a 2S pack and 11.4V for a 3S pack, roughly 3.8V per cell. Source: Medium storage guide.

How long can a LiPo stay fully charged? A day or two is normal between sessions. Smart packs start discharging to storage after 72 hours by default. Past that, storage-charge the pack down. Source: Medium storage guide.

Can I store LiPos in the fridge? No. A fridge brings moisture and condensation when the pack comes back out. A cool, dry room is enough, and a cold pack should return fully to room temperature before charging or use. Source: HobbyKing storage guide and Medium storage guide.

Is a slightly puffy pack still safe to use? No. Never use a LiPo that feels soft or has swollen. Retire it and dispose of it through a battery recycling point. Do not puncture it, press it flat, or charge it one more time. Source: Medium storage guide and DroneCamps storage guide.

How often should I check stored LiPo packs? Every two to four weeks, per the QRC storage guide. Source: QRC storage guide 19753.

Sources

Last updated: 2026-11-21

How to Charge a LiPo Battery: Balance Guide

To charge a LiPo battery, balance charge it: connect the main lead and the balance lead to a LiPo balance charger, set LiPo balance mode, match the cell count to the label, set the charge current to 1C, and stay in the room until every cell reads 4.20V. A 2200mAh pack charges at 2.2A at 1C, and a 5000mAh pack at 5A. Put the pack in a LiPo safe bag on a non-flammable surface first, and never charge a swollen, punctured, or hot pack. If you will not fly for more than a few days, use the charger storage mode instead of leaving the pack full.

What are the numbers that run every LiPo charge?

Every LiPo decision comes down to voltage per cell. A standard LiPo cell is 3.7V nominal, 4.20V when fully charged, and about 3.8V at storage voltage, the commonly cited figure, with several published guides giving a 3.80 to 3.85V range. Multiply the per-cell figure by the number of cells.

Pack Nominal (3.7V) Full (4.20V) Storage (about 3.8V) Minimum (about 3.0V)
1S 3.7V 4.2V About 3.8V About 3.0V
2S 7.4V 8.4V About 7.6V About 6.0V
3S 11.1V 12.6V About 11.4V About 9.0V
4S 14.8V 16.8V About 15.2V About 12.0V
6S 22.2V 25.2V About 22.8V About 18.0V

Three rules follow. Never charge a standard LiPo cell past 4.20V. Never run a cell below about 3.0V: cells run that low are damaged, and many chargers will refuse them. And the cell count on the charger must match the label: a 3S pack charged on a 4S setting is pushed toward 4S voltage. Sources disagree slightly on the exact storage figure and on the low-voltage floor, from 3.0V to 3.5V per cell, so follow the battery maker docs for your pack.

The other number is the charge rate, or C rate. 1C means a charge current in amps equal to the pack capacity in amp-hours: divide the capacity in mAh by 1,000. A 650mAh pack charges at 0.65A at 1C, a 2200mAh pack at 2.2A, and a 5000mAh pack at 5A. 1C is the safe default every published guide in the Sources list agrees on. Charge slower than 1C when the pack is old, has drifted cells, or sat unused for months. Charge faster than 1C only when the battery maker prints a higher charge rate on the label.

What gear do you need before you plug in?

Four items cover a first charging setup. The charger matters most: it must be a LiPo balance charger, not a NiMH or NiCd charger, which follows a different charging method and will damage a LiPo pack or overheat it. A balance charger has a balance port in addition to the main output, and it reads each cell through the balance lead while it charges.

  • A LiPo balance charger that covers your cell counts. A 2S and 3S only charger cannot charge a 4S or 6S pack.
  • The right leads. The main lead carries the full charge current, so it needs the plug that matches your pack, usually XT60 or XT30. The balance lead is the small multi-pin plug that lets the charger see each cell. If the balance lead is too short, or the plug does not match the charger port, use an adapter lead from the adapter-cable guide linked below.
  • A LiPo safe bag. Charge in a LiPo bag or fireproof container, on a non-flammable surface.
  • A cell checker. It reads each cell through the balance lead before you charge, so a weak cell shows up before current flows.

Do not charge with a phone charger or a USB power brick: a general USB charger has no balance port, no cell-count check, and no LiPo cutoff. The only USB option is a proper single-cell lithium charging module, such as the TP4056 module in the charger-choice guide.

How do you balance charge a LiPo, step by step?

Balance charge in this order every time: the charger must see the right cell count before current flows.

  1. Let the pack cool. After a run, wait until the pack is at room temperature: never charge a hot pack or a frozen or very cold pack.
  2. Inspect the pack. Do not charge a swollen, hot, leaking, punctured, or crushed pack. Check the balance lead wires and plug for damage.
  3. Put the pack in the safe bag. Set the bag on a non-flammable surface and put the pack inside, leads out where you can reach them.
  4. Read the label. A 3S 2200mAh pack is three cells and 2200mAh, so 1C is 2.2A.
  5. Connect the main lead. Red goes to positive, black goes to negative.
  6. Connect the balance lead. Plug it into the charger balance port, in the socket that matches the cell count. A 4-pin plug goes in the 3S socket, not the 4S socket. Never force a plug that does not fit.
  7. Set the charger. Select LiPo balance mode, not plain charge or fast charge, and enter the cell count and the charge current from step 4.
  8. Check the display. The charger should show the same cell count you entered and a voltage per cell for every cell. If it shows fewer cells, or a cell reads 0.00V, stop.
  9. Start the charge and stay in the room. The pack and the leads should stay cool, and the cell voltages should climb together. If a cell climbs much faster than the rest, or the pack gets warm, swells, or smells, stop.
  10. Stop when the charger reports full. Every cell should read 4.20V, or within about 0.03V of it. Unplug the balance lead first, then the main lead.

Plan on about 2 to 3 hours from empty at 1C for a complete balance charge, including the saturation stage where the cells equalize. The pack reaches about 70 percent in the first stage, and the saturation stage takes the rest of the time. A pack that finishes in minutes was nearly full already, or the charger cut off early on a fault.

What charge rate do you use?

Use 1C unless the battery maker states otherwise.

Pack capacity 1C charge current 0.5C charge current
650mAh 0.65A 0.33A
1300mAh 1.3A 0.65A
2200mAh 2.2A 1.1A
5000mAh 5.0A 2.5A

Two limits bind before the current limit does. The first is the charger wattage: charging power is roughly pack voltage times charge current, so a 3S 2200mAh pack at 1C needs about 24W, while a 6S 5200mAh pack at 1C needs about 115W. An 80W charger can deliver 1C to the small pack but not to the big one: it will simply deliver less current and take longer, which is the wattage limit, not a fault. The second limit is the pack label: if it prints a maximum charge rate, that is the ceiling. If it prints no charge rate, stay at 1C.

What do the charger modes do?

Most balance chargers offer the same five modes.

Mode What it does When to use it
Balance charge Charges the pack and equalizes each cell to 4.20V Every normal charge
Charge (no balance) Charges through the main lead only Avoid for multi-cell packs
Fast charge Ends the charge early When time matters more than the last few percent
Storage Brings the pack to about 3.8V per cell Packs that will sit for days
Discharge Drains the pack slowly Before disposal

Plain charge without the balance lead is the mode to avoid: the charger sees only the pack total, so it can stop while one cell sits over 4.20V and another sits under it. Fast charge saves minutes and costs pack life, because it skips the stage where the cells are evened out.

How do you storage charge a pack?

A pack that will sit for more than a few days goes to storage voltage, about 3.8V per cell, the commonly cited figure; several published guides give a 3.80 to 3.85V range. A pack left full at 4.20V per cell for weeks degrades faster, and a pack left flat degrades faster still.

Storage mode works in both directions: it charges a flown pack up, and it discharges a full pack down to it. Run storage mode after every session for packs you will not use within a day or two, and check stored packs every few weeks. For the full storage routine, read the storage guide linked below.

How do you charge a LiPo for the first time?

New packs usually arrive at roughly storage voltage. Before the first run, balance charge the pack at 1C or less, then check that all cell voltages ended within a few hundredths of a volt of each other. A new pack with one cell far off the others is worth reporting to the seller. There is no break-in ritual that a normal balance charge does not cover. Keep the first runs gentle. Do the same for any pack that sat unused for months: charge it at 0.5C the first time back, and retire it if one cell will not hold voltage after balancing.

What about LiHV and LiFe packs?

LiHV and LiFe packs are not standard LiPo packs, and they need their own charger settings. LiHV cells charge to 4.35V per cell instead of 4.20V and need the LiHV setting; charging a normal LiPo on it overcharges it. LiFe cells use their own setting with a full voltage of about 3.6V per cell. Always check the label: the chemistry is printed on the pack, and the setting must match it.

Can you charge more than one pack at once?

Yes, on a parallel balance board, if every pack follows three rules: same cell count, voltages within 0.1V per cell of each other before you connect anything, and charge current set for the combined pack. Six 1300mAh packs in parallel are one 7800mAh pack, so 1C is 7.8A total. Always use balance mode on a parallel board, never fast charge, and stay in the room. Use a fused board. The full rules are in the adapter-cable guide linked below. Parallel charging is not a beginner technique: if you cannot read each cell on every pack with a checker first, charge the packs one at a time.

What mistakes ruin packs or start fires?

Most LiPo fires trace to a small set of avoidable mistakes.

Mistake What happens Fix
Charging on NiMH or NiCd mode Wrong voltage curve, overcharges the pack Always select LiPo balance mode before you start
Wrong cell count on the charger Charger pushes a 3S pack toward 4S voltage Match the display to the label before you press start
Charging through the main lead only Charger cannot see single cells, cannot balance Connect the balance lead every time
Leaving a charge unattended A fault burns unchecked Stay in the room for the whole charge
Charging a swollen or punctured pack Damaged cell vents or catches fire Retire the pack, never charge it
Charging on a flammable surface A fault has fuel at once LiPo safe bag on a non-flammable surface
Storing packs full for weeks Cells degrade at full voltage Storage charge to about 3.8V per cell when the pack sits

Charging on NiMH mode is the classic beginner error: the charger pushes current with the wrong cutoff, and the pack has no protection against it. Leaving a charge unattended turns every other mistake into a fire: a fault caught in the first minute is a ruined pack, while the same fault caught an hour later is a burned bench.

Why is my charger showing an error or a low cell?

Work through the cause in order, cheapest check first.

The charger shows fewer cells than the pack has. The balance lead is not fully seated, or it is in the wrong socket. Reseat the plug on both ends, and check that a 4-pin plug is in the 3S socket. Try the pack lead directly into the charger, skipping any adapter: if the cell count comes back, the adapter is the fault.

One cell reads much lower than the rest. Cells drift with age and use. Run a full balance charge at 0.5C and check again. If one cell stays far off after balancing, retire the pack.

The charger reports a low-voltage error and will not start. One or more cells dropped below the safe level, typically about 3.0V per cell. The pack was run too flat, left plugged in, or stored flat. Do not force it by charging on NiMH mode: that bypasses the safety cutoff that refused the pack for a reason. If a cell reads 0.00V, the pack is done. Retire it and dispose of it following local rules.

The pack gets hot or swells during charging. Stop the charge at once. Move it outdoors on a non-flammable surface if it is safe to do so, and keep people away. A puffed LiPo is a fire risk: do not charge it, recover it, or use it.

Which charger setup should you buy?

Buy for the packs you own. Four profiles cover most pilots.

First RC car or plane, 2S and 3S packs only. Buy the ImaxRC B3 Pro Balance Charger (2S/3S) (ID 16863) at $15.99. Treat it as a starter: the moment you add a 4S pack, you need a charger that covers 4S.

Small bench work, single cells. Buy the TP4056 5V Micro USB 1A Lithium Battery Charging Module (ID 16875) at $1.49, or the 5-pack (ID 83) at $1.99. It charges one lithium cell at 1A and must never be used to charge a series pack.

FPV fleet, 1S to 6S packs, one charger. Buy the B6 80W Mini LiPo Balance Charger and Discharger with Power Supply (ID 18960) at $42.99 on sale (regular $51.99). It covers 1 to 6 cells, includes the power supply, and takes XT60, JST, and T connectors. Add the 3-in-1 Battery Voltage Checker Balancer and Discharger (ID 12052) at $12.49 to read each cell before every charge.

Big 6S packs at full 1C. Buy the B6neo 2 Smart Charger, DC 300W / PD 80W (ID 7225) at $84.99 for the US Plug variation. A 6S 5200mAh pack at 1C needs about 115W, past an 80W input, so plan on the 300W DC input for big packs; the PD input at 80W covers small packs. A Blue variation is also listed at $99.99.

Add a LiPo safe bag before any of it if you do not already own one: the Zeee Small LiPo Safe Bag, Fireproof Pouch, 11 x 8.7in (ID 20106) is $11.99 on sale (regular $14.99). If your balance lead is short or the plug does not match your charger port, add the JST-XH balance extension leads from the adapter-cable guide below.

Parts used in this guide

Prices and stock were verified live on 2026-11-21. All five items below are in stock and purchasable.

Shipped fast and securely from our secure facility in Queensbury, NY. QRC ships within the USA only.

Related guides

FAQ

How long does it take to charge a LiPo battery? About 2 to 3 hours from empty at 1C for a complete balance charge, including the saturation stage where the cells equalize. The pack reaches about 70 percent in the first stage. A pack that finishes in minutes was nearly full already. Source: Battery University BU-409.

Can I charge a LiPo battery without a balance charger? You can charge through the main lead only, but the charger cannot see single cells that way, so it cannot balance them. One cell can end up overcharged while the pack total looks right. Source: EuroRC charging guide and SwellRC charging guide.

What is the storage voltage for a LiPo battery? About 3.8V per cell, with several published guides giving a 3.80 to 3.85V range. A 3S pack stores at about 11.4V. Use the charger storage mode. Source: SwellRC charging guide, FPV Bible charging guide, and Tech1RC safety guide.

Can I leave a LiPo battery charging overnight? No. Charge only when you can watch it, and store packs at storage voltage instead of keeping them full. Source: SwellRC charging guide and EuroRC charging guide.

What do I do if one cell is below 3.0V? Stop. Do not force it by charging on NiMH mode. Most chargers refuse to start below about 3.0V per cell, and a cell that reads 0.00V means the pack is done. Retire it and dispose of it following local rules. Source: HobbiesDirect not-charging guide and SwellRC charging guide.

Can I charge a LiPo battery with a phone charger? No. A general phone charger or USB power brick has no balance port, no cell-count check, and no LiPo cutoff. The only USB option is a proper single-cell lithium charging module, such as the TP4056 module. Source: QRC charger-choice guide and MakeUseOf charging guide.

How do I know my LiPo battery is fully charged? Every cell should read 4.20V, or within about 0.03V of it. Check the per-cell display, not just the pack total. Source: QRC adapter-cable guide and SwellRC charging guide.

Sources

Last updated: 2026-11-21